KVAR RATING CALCULATOR,CAPACITOR BANK SIZE CALCULATION

Image
  Determination of Required Capacitor Rating by measurement 3 Methods are used. 1. Measurement with current and power factor 2.Measurement with recording of Active and Reactive power. 3.Measurement by Reading Meters . 1 . Measurement with Current and power factor The active power P is calculate from the measured voltage V ,apparent current Is and Power Factor P=√3*Voltage*apparent Current*cosψ *10^-3 If the desired power factor cosψ has been specified, the capacitor power rating can be calculate from the following formula: Qc = P. (tan ψactual - tanψ desired) Let's See the Example Measured Apparent Current Is : 248 Amps Power Factor cos ψ1 = 0.86 Desired Cos ψ2 = 0.92 Voltage V :397 V p=√3 * 397 * 248 * 0.86 * 103 P = 146.6 KW Qc= P. (tanψ actual - tanψ desired) = 146.6(0.59 - 0.42) = 24.9 KVAR

ASTM E10-15 BRINELL HARDNES NUMBER IS CALCULATED AS

 BRINELL HARDNESS NUMBER (HBW)


HBW =  2xFkgf  /πD(D-D2-d2)

Fkgf = Test Force in kgf

D      = Diameter of the indenter ball in mm

d      = Measured mean diameter of the indentation in mm


Ball Diameter = D=10 mm

Test Force = Kgf = 3000

BRINELL HARDNESS NUMBER CALCULATION
Brinell Hardness Number Equation & Solution

Comments

Popular posts from this blog

TOLERANCE OR MAXIMUM PERMISSIBLE ERROR OR ACCURACY OF VERNIER OF DIGITAL CALIPER AS PER BS EN ISO 13385-1:2019

HOW TO CALCULATE THE UNCERTAINTY BUDGET OF pH METER.

Estimation of Uncertainty in Hardness Measurement & Maximum Permissible Error of Brinell Hardness Testing Machine As Per ISO 6506-2 & ASTM E10-15